『Before and after the flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. Is the front 5 and back 3 of the flowmeter still the front 10 and back 5?
The requirements for the straight pipe sections before and after the flowmeter are usually the front 10 and back 5, but there are also situations where the front 5 and back 3 are required. one The top 10 and bottom 5 are more common: generally speaking, most flow meters require the length of the upstream straight pipe section to be 10 times the pipe diameter, and the downstream to be 5 times the pipe diameter. This is to ensure that the fluid flow entering the flowmeter is stable and uniform. A sufficiently long straight pipe section upstream can fully develop the turbulent flow generated by various pipe fittings (such as elbows, valves, etc.) into stable laminar flow, while a straight pipe section downstream helps to ensure the stability of the measured fluid, reduce interference with the measurement results, and make the measurement more accurate. two Special case of front 5 and back 3: Under certain conditions, such as stable fluid properties, ideal flow conditions, or less stringent upstream flow requirements for flow meters, the straight pipe section requirements of front 5 and back 3 may be used. However, this situation is relatively rare, and the appropriate length of the straight pipe section needs to be determined based on the type of flowmeter, user manual, and actual working conditions.
2. How much straight pipe length should be left before and after the installation of the flowmeter? Do you have any specific requirements!
For metal tube rotor flow meters, the standard of the Ministry of Machinery stipulates that the front straight pipe section should be at least 10 times the diameter of the flow meter, star


Current position > Product detail